Teledyne Simtronics GD10P CO2 Infrared Point Gas Detector

  1. Home
  2. Products

Teledyne Simtronics GD10P CO2 Infrared Point Gas Detector

The GD10P-CO2 uses state-of-the-art IR gas measurement to give a fast, reliable response. The GD10P has set the standard for gas detection in the areas of safety, stability and low maintenance.

The GD10P comes with a 5-year warranty. The GD10P-CO2 has been designed with features that provide an effective response to the detection of CO2 in a wide range of industrial environments, from boiler plant rooms to offshore petrochemical installations.

The GD10P-CO2 differs from all other point infrared gas detectors because it utilises silicon-based solid-state sources.

The complete optomechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

Offering the longest combined detector and IR source warranty on the market. Supplied with worldwide hazardous area approvals. An industry standard HART interface is used for configuration of special fault levels as well as access to extended maintenance data.

Features

  • Solid state IR sources (SimSource) for superior long-term performance compared to filament lamps.
  • Dual-layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand).
  • Low power consumption reduces the load on the UPS.
  • Independently heated mirror and lens for high-performance detection in rough environmental conditions.
  • The integral termination compartment enables reduced installation time, and the unit is ready out of the box.
  • No recalibration is required; it monitors and accounts for all changes in the optical path, thanks to its true dual-path, double-compensation optical design.

Other Versions

  • GD10P Combustible gas detector
  • The PE model detects flammable gas in large volumes of air

Order Information

GD10P Detector Range

ATEX / IECEx Approved
Model Description
GD10-P00-23AN-0XH-00 CO2 10,000 ppm, SS316L, ATEX, IECEx, HART
GD10-P00-23BH-0XH-00 CO2 3% Vol., SS316L, ATEX, IECEx, HART
GD10-P00-23BC-0XH-00 CO2 5% Vol., SS316L, ATEX, IECEx, HART
GD10-P00-23BD-0XH-00 CO2 10% Vol., SS316L, ATEX, IECEx, HART
GD10-P00-23BJ-0XH-00 CO2 25% Vol., SS316L, ATEX, IECEx, HART
GD10-P00-24BC-0XH-00 CO2 5% Vol. (CH4 immune), SS316L, ATEX, IECEx
GD10-P00-24BG-0XH-00 CO2 100% Vol. (CH4 immune), SS316L, ATEX, IECEx
CSA Approved
Model Description
GD10-P00-23AN-0BH-00 CO2 10,000 ppm, SS316L, CSA, HART
GD10-P00-23BH-0BH-00 CO2 3% Vol., SS316L, CSA, HART
GD10-P00-23BC-0BH-00 CO2 5% Vol., SS316L, CSA, HART
GD10-P00-23BD-0BH-00 CO2 10% Vol., SS316L, CSA, HART
GD10-P00-23BJ-0BH-00 CO2 25% Vol., SS316L, CSA, HART
GD10-P00-24BC-0BH-00 CO2 5% Vol. (CH4 immune), SS316L, CSA
GD10-P00-24BG-0BH-00 CO2 100% Vol. (CH4 immune), SS316L, CSA
UL Approved
Model Description
GD10-P00-23AN-0CH-00 CO2 10,000 ppm, SS316L, UL
GD10-P00-23BH-0CH-00 CO2 3% Vol., SS316L, UL
GD10-P00-23BC-0CH-00 CO2 5% Vol., SS316L, UL
GD10-P00-23BD-0CH-00 CO2 10% Vol., SS316L, UL
GD10-P00-23BJ-0CH-00 CO2 25% Vol., SS316L, UL
GD10-P00-24BC-0CH-00 CO2 5% Vol. (CH4 immune), SS316L
GD10-P00-24BG-0CH-00 CO2 100% Vol. (CH4 immune), SS316L
Accessories
Model Description
499-811176 Adapter plate
599-811547 Adapter plate GD100-GD10P
Installation
Model Description
AS053-X SS316L Mounting Plate
AS057-X U-bolts for 2″ pipe
AS058-X U-bolts for 2.5″ pipe
AS049 Wall Mount Adapter
499-811938 Duct Mount Kit
Protection
Model Description
499-813397 Mosquito Net
499-815712 Sunshade
Maintenance
Model Description
599-818154 Gas Test Socket
499-810874 Sample Flow Housing
140-816580 Hand-held Terminal
TLU600 IR Remote Control Unit
TLH710 HART Remote Control Unit
Display
Model Description
GD10P-DISPLAY-A-ATEX Loop-powered Indicator, ATEX
GD10P-DISPLAY-A-CSA Loop-powered Indicator, CSA
GD10P-DISPLAY-X-ATEX SS Indicator, ATEX
GD10P-DISPLAY-X-CSA SS Indicator, CSA
R-5000AL-2 Display Module Aluminium
R-5000SS-2 Display Module Stainless Steel
Spares
Model Description
373-901337 Terminal GD10P
499-810913 Front Cover GD10P
599-810646 Test Nipple
599-904176 Protective Cap

General Specifications

Detection Method IR-absorption, dual wavelength, dual path
IR Source Solid state IR source, 50Hz flash
Gases Detected CO2
Self-test Continuous
Calibration Factory set, no field recalibration
Configuration HART (response time, fault levels)

Performance

Accuracy ±5% FS (0-50%), ±7% FS (50-80%)
Response Time T20 = 1 sec (0.3 sec), T50 = 2.5 sec (0.7 sec), T90 = 6 sec (1.6 sec)

Output Signal

Standard Current source 4–20 mA, max load 500 ohm
Option Current sink 4–20 mA
HART Maintenance and configuration
Detector Warnings Early clean optics – Pre warning (2 mA)
Dirty optics – Dirt accumulation (1 mA)
Detector failure – Internal fault (0 mA)

Electrical

Power Supply 24V DC (18–32V DC)
Power Consumption Approx. 3.5 W
Connection 3 wires (0.5mm² – 2.5mm²)
Cable Entry M20 Exe cable gland

Temperature Range

Storage -40°C to +70°C
Operating -40°C to +60°C
Humidity 100% RH

Explosion-Proof Housing

Protection IP66/IP67
Material Stainless Steel (SIS2343 / ASTM316)
Weight Approx. 2.9 kg
Dimensions 251 x 104 x 105 mm (9.89 x 4.1 x 4.13 in)

Warranty

Instrument 5 Years
IR Source 15 Years

Approvals

ATEX / IECEx / INMETRO II 2G Ex de IIC T6 Gb
CSA Ex de IIC T6
Classification Class I, Division 2, Groups A, B, C, D
Other SIL2 (Software SIL3), ABS, MED

Versions

Standard Ranges 10000ppm (1%), 3%, 5%, 10%, 100%
Note 0–100% volume compensated for Methane interference

Front Cover Options

Weather Protection Standard point detector
Sample Flow Housing Sampling systems and testing
Duct Mount Kit Through-wall installation

Accessories

Mosquito Net Extra insect protection
Sun Shade Protection from extreme radiation

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent
Error occurred while sending email. Please try again later.