Honeywell ACM 150 FTIR Analyser

  1. Home
  2. Products

Honeywell ACM 150 FTIR Analyser

Lower your cost-per-point gas monitoring with next-generation FT-IR technology.

The ACM 150 uses versatile and proven Fourier Transform Infrared Technology to detect a wide range of volatile chemicals. It uses the infrared fingerprint of each gas for identification, which is free of cross-interferences. It can also identify unknown chemicals or odours.

Detection of new gases can be added at any time. By choosing between two sample cells, the ACM can detect either ppm levels for toxic gases or per cent levels for flammable gases.

The gas selections and alarm configuration for each point can be easily configured or changed either from the front panel or remotely via a web browser. Up to 14 gases can be detected at each point. Up to 4 points can be sampled together for increased speed. Because of its modular design and built-in diagnostics, the ACM is easy to maintain.

An optional LonWorks interface is ideal for connection to Honeywell Analytics’ Life Safety System.

Integrate gas detection into a single unit:

  • Detect multiple gases, chemicals, or odours in an industrial process*.
  • Overlay the spectrum of detected gas against a library of spectra for precise detection as a user validation tool.
  • Up to 40 measuring points can be detected sequentially.
  • 80 configurable relay points for increased flexibility.

Promote uptime:

  • Sealed aluminium body prevents moisture intrusion, protecting critical internal components.
  • Double IR scan ensures reliable performance and reduces false alarms.
  • Optimised built-in measurement and self-diagnostic capabilities eliminate the need for on-site gas calibration.
  • Desiccant replacement cycle of 3 to 5 years.

Boost gas monitoring performance:

  • Composite sampling of up to four measuring points provides faster measurement.
  • Easy-to-service gas cell with stainless-steel body construction prevents costly downtime.
  • Better signal-to-noise ratio (SNR) performance allows for lower LDL measurements.

Simplified touchscreen operation:

  • Improved HMI with a modernised solid-state computer operating on a world-proven operating system.
  • Large user-friendly touchscreen interface.
  • Flexible communications options meet unique site requirements.
  • Robust solid-state drive.
  • Embedded web server for remote access.
  • Refer to the ACM 150G2/100 Gas List or ask your regional sales rep for more information. More than two hundred gases are detectable. Our engineers may be able to generate a new method for gases not listed.

Order Information

ACM 150 System Range

ACM 150 Base Unit
76-ACM150-115-1G2 ACM150 120VAC, primary venturi pump version
76-ACM150-115-2G2 ACM150 120VAC, primary electric pump version
76-ACM150-230-1G2 ACM150 240VAC, primary venturi pump version
76-ACM150-230-2G2 ACM150 240VAC, primary electric pump version
ACM Method Development
100-12899-00 Method Generation / Setup (per gas)
Chemistry / Application Support & Development
1991-0199 1 hour lab/development time (min 4 hrs)
1991-0200 Full day lab/development time (8 hrs)
1991-0202 Full week lab/development time (40 hrs)
ACM 150 Options and Accessories
76-150-14393-04-1 10-point Sample Manifold with Dust Filter
76-165-14594-00-1 Line Leak Kit, 3/8T Check Valve
RSD0013 Setup of method
0235-0252 FEP tubing 0.25″ ID x 0.375″ OD, 300m
76-215-12477-00-B Line Leak hardware (dual electric pump)
76-215-12475-00-D Line Leak hardware (Venturi pump)
ACM 150 Serial Communication Interfaces
76-150-14392-02 ControlNet Interface Kit
76-150-14398-02 ControlNet Redundant Interface Kit
76-150-14391-10 Modbus TCP/IP Interface Kit
76-150-14390-04 Profibus DP Interface Kit
ACM 150 Spares
76-465-15101-00 PKI Bench with Plate
76-441-15551-00 Gas Cell for PKI Bench
76-150-15300-00-C Network Switch (Cisco)
76-150-14500-01-A DVD/CD Kit with Mounting
76-150-14600-00-A Single Board Computer Kit
3014B1212 ACM100 Complete Upgrade Kit
3014B1213 ACM150 HMI Upgrade Kit
3014B1214 Touch LCD Module (Spare)
3014B1215 HMI PC Module (Spare)
ACM 100 Upgrade Kits
76-165-14582-00-1 Dust Filter Kit 3/8
ACM 100 Spares
76-215-12477-00-B Line Leak hardware (dual electric pump)
76-215-12475-00-D Line Leak hardware (Venturi pump)
76-220-13588-00-A Adaptor Solenoid Valve
76-120-15050-00 ACM 100 Archiving Software

Specifications

700 Series Catalytic Combustible Gas Detection

Category Part Number Description
Sensor Assemblies (Catalytic) 967-525520-100 FP-700 Catalytic LEL Gas Sensor Assembly (No Condulet)
967-521520-100 FP-700 Catalytic LEL Gas Sensor Assembly (Aluminium Condulet)
967-524520-100 FP-700 Catalytic LEL Gas Sensor Assembly (316SS Condulet)
9H7-521520-100 FP-700 Catalytic LEL Gas Sensor with HART Bridge (Aluminium)
9H7-524520-100 FP-700 Catalytic LEL Gas Sensor with HART Bridge (316SS)
9R7-521520-100 FP-700 Catalytic LEL Gas Sensor with RAM (Aluminium)
9R7-524520-100 FP-700 Catalytic LEL Gas Sensor with RAM (316SS)
9K7-521520-100 FP-700 Catalytic LEL Gas Sensor with HART + RAM (Aluminium)
9K7-524520-100 FP-700 Catalytic LEL Gas Sensor with HART + RAM (316SS)
Integration Modules 975-70000A-00A Remote Control / Alarm Relay Module (Aluminium Enclosure)
975-70000A-00S Remote Control / Alarm Relay Module (316SS Enclosure)
975-70000H-00A Remote Control / Alarm Relay Module with HART (Aluminium)
975-70000H-00S Remote Control / Alarm Relay Module with HART (316SS)
975-70005H-00A HART Integration Module (Aluminium)
975-70005H-00S HART Integration Module (316SS)

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent