Now obsolete, replaced by the S5000 Gas Monitor
The IR4000S Single-Point Monitor is a display and user interface for the IR400 point IR gas detector.
The monitor allows local calibration and displays gas concentration. It is housed in an explosion-proof junction box enclosure that can be installed in hazardous locations adjacent to the detectors.
Relays are optional. The relays provide output for Alarm, Warn, and Fault conditions.
32491-3A = CONTROL BOARD, MODBUS, PUSH TERMINAL, IR4000S
32491-5A = CONTROL BOARD, MODBUS, SCREW TERMINAL, IR4000S
32491-6A = CONTROL BOARD, CO2, PUSH TERMINAL, IR4000S
30060-1 = CALIBRATION MAGNET
| Classifications |
Class I, Divisions 1 & 2, Groups B, C, & D, Type
4X Class I, Zone 1, IIB + H2 (Ta=-40° C to +75° C) Ex d, IIB + H2 T5 Gb Ex tb IIIC, T100° C Db, IP66 (Ta=-60° C to +75° C) |
| Warranty | Two years |
| Approvals |
ATEX, IECEx, CE, MED (IR4000S), DNV(IR4000S), FM 6310/6320 & CSA 22.2 No. 152 Performance approved HART registered (IR4000M) SIL 2 suitable (FM) |
| Operating Temperature Range | -40° F to +167° F (-40° C to +75° C) |
| Storage Temperature Range | -58° F to +185° F (-50° C to +85° C) |
| Humidity Range | 10% to 95% RH, non-condensing |
| Length | 6.5″ (165 mm) |
| Width | 6.0″ (152 mm) |
| Height | 3.21″ (82 mm) |
| Weight | 5.5 lbs (2.5 kg) |
| Mounting Holes | 5.05″ (127 mm) center to center |
| Housing |
Aluminum 6061-T6 alloy (cover) A356-T6 alloy (base) or 316 stainless steel |
| Input Power |
IR4000M: 20-36 VDC @ 100 mA max IR4000S: 20-36 VDC @ 83 mA max 24 VDC nominal |
| Analog Signal |
0-21.7 mA (600 ohms max.-IR4000M) 0-21.7 mA (500 ohms max.-IR4000S) |
| Status Indicators | Three-digit LED display with gas concentration, Warn and Alarm LEDs, calibration prompts, fault codes, and setup options |
| Relay Ratings (Optional) |
8 A @ 250 VAC / 8 A @ 30 VDC res. Max. (3x) SPDT – Warning, Alarm & Fault |
| RS-485 Output (Optional) | Single Modbus (IR4000S) or dual redundant Modbus RTU (IR4000M), suitable for linking up to 128 units or up to 247 units with repeaters |
| Baud Rate | 2400, 4800, 9600, or 19200 BPS |
| HART (Optional) |
HART 6, HART Device Descriptor available. AMS aware |
| Faults Monitored | Re-calibration error, EPROM Checksum error, Optics failure / blockage; low supply voltage, EEPROM checksum error, reference or active lamp failure, heater failure, time to re-zero unit |
| Cable Requirements |
Max. distance between IR4000 and power source @
24
VDC nominal (20 ohm loop): 14 AWG (2.0 mm2) – 2606 ft (794 m) Max. distance for analog output (500 ohms max): 14 AWG (2.0 mm2) – 9000 ft. (2740m) |
| Wireless Communication | Available with ELPRO Technologies wireless devices |
| IR4000S | IR4000S-0-0-02-1-0-1 IR400 (methane, 0-20 mA, splash guard w/screen), no relays, aluminum |
| IR4000M | IR4000M-0-0-00-1-0-1-1 No relays, no Modbus, detector sold separately IR400 (methane, 0-20 mA, splash guard w/screen), no relays, aluminum |
| Size |
Flush mount box: H76 x W54 x D24 mm (3 x 2.12 x
0.94ins) External mask: H118 x W118 x D14 mm (4.64 x 4.64 x 055ins) |
| Weight | 0.2kg |
| Enclosure Material | Polycarbonate |
| Ingress Protection | IP42 |
| Power | 12-24 Vdc or 90-240Vac |
| Electrical Output |
2 relays RS485 serial output |
| Operating Temperature | -10 / +50°C |
| Humidity | 0 / 95% RH non condensing |
| Compliance |
EMC: EN 61000-6-3:2007 + A1:2011; EN
50270:2015 Refrigeration Standards: EN 378-3; EN 14624; EN 50676; IEC 60335-2-40 Annex LL; ISO 5149-3; F-Gas Regulation |