Drager Electrochemical (EC) Sensors

  1. Home
  2. Products

Drager Electrochemical (EC) Sensors

Fast response, high accuracy, excellent stability, and long life. Electrochemical Drager Sensors offer all these benefits. You can use the robust, long-life sensors for selective measurement of the lowest concentrations of toxic gases and oxygen in ambient air.

Long lifetime

The electrochemical sensors are designed to provide reliable, stable measurements over a long period of time. The use of resistant plastics, such as PTFE, and the purest catalysts makes this possible. Additionally, a huge electrolytic reservoir and large electrode areas provide sufficient reserves for a long lifetime. The construction of the DragerSensors offers you long stability and a low age-related drift

Ready for immediate use

All DragerSensors are factory calibrated with the target gas. These values are saved in the internal, electronic memory. You can use the sensors in the field immediately. For some sensors, other target gases can be selected from the internal gas library.

Comprehensive range of applications

All sensors have an internal temperature sensor. Between -40 °C and +65 °C, the temperature influence is compensated for zero and sensitivity. The patented internal pressure compensation balances adverse ambient conditions, such as humidity changes or barometric variation. As a result, you can use the sensors even at high or low pressure. For some sensors, you can reduce the cross-sensitivities that cause disturbances by combining selective filters.

Performance features

  • Fast response.
  • Low detection limits.
  • Comprehensive self-diagnosis options.
  • it is possible to choose between oxygen sensors for partial-pressure or volume percentage measurement.
  • Sensors with organic electrolyte for detection limits in the lower ppb range.
  • Acid gas sensor (AC) with an unlimited lifetime, due to a refillable electrolyte.

Order Information

Gas Detection Sensors

Target Gas Drager Sensor Part Number Detection Limit (Vol%) Max Range (Vol%) Comment
Oxygen O2 6809720 0.5 100 Partial pressure
Oxygen O2 LS 6809630 0.5 25
Target Gas Drager Sensor Part Number Detection Limit (ppm) Max Range (ppm) Additional Gases
Ammonia NH3 TL 6813095 1 300 Amines
Ammonia NH3 FL 6813260 1 300
Ammonia NH3 HC 6809645 30 1000
Ammonia NH3 LC 6809680 5 300 Amines
Carbon monoxide CO LS 6809620 10 5000
Carbon monoxide CO LH 6812570 15 300
Carbon monoxide CO 6809605 5 1000
Chlorine Cl2 6809665 0.05 100 Halogene
Ethylene oxide OV1 6810740 5 200 Organic vapours
Ethylene oxide OV2 6810745 5 100 Organic vapours
Hydrazine Hydrazin 6810180 0.02 5 Derivitives
Hydrogen H2 6809685 15 3000
Hydrogen chloride AC 6810595 0.5 30 Acidic compounds
Hydrogen chloride HCl 6809640 1 100 Halides
Hydrogen cyanide HCN 6809650 1.5 50
Hydrogen cyanide HCN LC 6813200 0.1 50
Hydrogen peroxide H2O2 HC 6809675 100 7000
Hydrogen peroxide H2O2 LC 6809705 0.1 300
Hydrogen sulfide H2S HC 6809710 10 1000
Hydrogen sulfide H2S LC 6809610 1 100 Mercaptane
Hydrogen sulfide H2S 6810435 0.5 100
Nitrogen dioxide NO2 6809655 0.3 100
Nitrogen dioxide NO2 LC 6813205 0.05 20
Nitrogen monoxide NO 6809625 3 200
Ozone Ozon 6814005 0.02 5
Phosgene COCl2 6809930 0.02 20
Phosphine Hydride 6809635 0.03 20 Hydrides
Phosphine PH3 / ASH3 6809695 0.02 20
Phosphine Hydride SC 6809980 0.01 1 Hydrides
Sulfur dioxide SO2 6809660 0.5 100
Accessories
Calibration bottle 6803407
Dust filter 6809595
Dust filter T stamped 6812224
Selective filter A2F 6809684
Selective filter K2F 6809933
Selective filter NF 6809643
Selective filter HSF 6809862
Selective filter MF 6809638
Selective filter K1F 6809663
Viton Calibration adapter 6810536

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent
Error occurred while sending email. Please try again later.