The SMART P detectors from Sensitron have been designed to fulfil the latest European Standard on gas detection in car parks, with the capability to detect CO, NO2 and petrol vapours.
The build-up of toxic gases from cars can be deadly, which is why extra care needs to be taken in confined areas, such as car parks. The SMART P detectors are designed specifically for measuring gases in car parks, capable of detecting CO, NO2, and petrol vapours to provide complete peace of mind.
While the SMART P-1 is a single-gas detector, the SMART P-2 allows for simultaneous detection of both CO and either NO2 or petrol vapours, offering enhanced protection from noxious fumes.
Both the SMART P-1 and P-2 offer RS485 communication as standard, and have been designed to fulfil the latest European Standard for gas detection in car parks (EN 50545-1:2011), so you know you’re fully covered.
CR2398CO Smart P1, Carbon Monoxide CO EC 0-300 ppm, RS-485.
CR2399ND Smart P1, Nitrogen Dioxide NO2 0-30 ppm, RS-485.
CR2400CO-ND Smart P2, Carbon Monoxide CO EC 0-300 ppm & Nitrogen
Dioxide NO2
EC 0-30 ppm, RS-485.
CR2400CO-VB Smart P2, Carbon Monoxide CO EC 0-300 ppm & Petrol
Vapour Cat
0-100% LEL (Supplied with remote sensor head with 130cm cable).
K2398CO CO detector for car parks with RS-485 serial outputs.
Range 0-300
ppm.
K2399ND NO2 detector for car parks, RS-485 serial outputs. Range
0-30 ppm.
K2398CO Carbon Monoxide & NITROGEN DIOXIDE detector for Car
Parks, RS485
Serial Output. Range 0-300 ppm CO and 0-30 ppm NO2.
K2399ND Carbon Monoxide & NITROGEN DIOXIDE detector for car
parks, RS485
serial output. Range 0-300 ppm CO and 0-30 ppm NO2.
K2398CO Carbon Monoxide & Petrol Vapours Detector for Car Parks,
RS485
Serial Output. Range 0-300 ppm CO and 0-100% LFL Petrol Vapours.
K2400VB Supplied with a remote sensor head, complete with a
130cm cable.
SK3123 Base board for SMART P.
Accessories
STS/CKD+ Enhanced calibration keypad with 7-digit display and SD card slot. Compatible with Smart series for operations like zero/span calibration and monitoring 4-20 mA signals.
| Specifications | |
|---|---|
| Size |
Box: H100 x W100 x D52 mm (3.9 x 3.9 x 2ins) Cover: H105.8 x W105.8 x D7.8 mm (4.2 x 4.2 x 0.3ins) |
| Weight | 0.25kg |
| Enclosure material | Polycarbonate |
| Ingress Protection | IP55 |
| Connection | 2 x M20 |
| Power | 12-24 Vdc |
| Electrical output | RS485 serial output |
| Operating temperature | -20 / +50°C |
| Humidity | 15 / 90 %RH |
| Compliance |
EMC EN 50270:2015 Car park standard EN 50545-1:2011 |
Get in touch with us to see how we can help you with your project