The SMART 3G-D3 Gas Detector with Infrared sensor is designed to meet industrial requirements; the enclosure is explosion-proof and can be installed in ATEX Zone 2 and, when equipped with a dust adapter, in Zone 22.
The sensing element is placed in the stainless steel head with a 47.5 mm diameter. The infrared sensors employed for flammable and refrigerant gas detection are poison-free, with high accuracy and a long lifetime.
The gas detector has a 12-24 Vdc power supply, a standard 4-20 mA 3-wires output, and three relays. Optionally, the SMART3G-D3 can be equipped with serial RS485 communication.
The enclosure has dimensions 106 x 160 x 81 mm; on the upper side, there’s a M20 cable gland. The SMART3G-D3 features a 7-segment display for real-time concentration visualization and Hall effect sensors for non-intrusive field calibration.
SMART3G-D3 is SIL2 hardware and SIL3 software with a redundant system; the hardware is SIL3.
| Sensor Part Number | Description |
|---|---|
| SMART3G-D3 – FLAMMABLE GAS (Infrared sensor) | |
| S2625ME | METHANE detector, 4-20 mA, 0-100% LFL |
| S2601PR | PROPANE detector, 4-20 mA, 0-100% LFL |
| S2601BU | BUTANE detector, 4-20 mA, 0-100% LFL |
| S2601GP | LPG detector, 4-20 mA, 0-100% LFL |
| S4434R454B | R454B detector, 4-20 mA, 0-100% LFL |
| S4828R454C | R454C detector, 4-20 mA, 0-100% LFL |
| S3426R32 | R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL |
| S3430R1234YF | R1234yf detector, 4-20 mA, 0-100% LFL |
| S3435R1234ZE | R1234ze detector, 4-20 mA, 0-100% LFL |
| SMART3G-D3 – CO2 (Infrared sensor) | |
| S2631CO2 | CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA |
| S2632CO2 | CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA |
| S2447CO2 | CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA |
| S2448CO2 | CARBON DIOXIDE (CO2) detector, 0-5000 ppm, 4-20 mA |
| S2633CO2 | CARBON DIOXIDE (CO2) detector, 0-100% Vol., 4-20 mA |
| SMART3G-D3 – SF6 and REFRIGERANT GASES (Infrared sensor) | |
| S3943R32 | R32 detector, 0-2000 ppm, 4-20 mA |
| S3597R134A | R134a detector, 0-2000 ppm, 4-20 mA |
| S3600SF6 | SF6 detector, 0-2000 ppm, 4-20 mA |
| S3651R125 | R125 detector, 0-2000 ppm, 4-20 mA |
| S3652R1234YF | R1234yf detector, 0-2000 ppm, 4-20 mA |
| S3947R1234ZE | R1234ze detector, 0-2000 ppm, 4-20 mA |
| S3653R404A | R404A detector, 0-2000 ppm, 4-20 mA |
| S3654R407A | R407A detector, 0-2000 ppm, 4-20 mA |
| S3919R407F | R407F detector, 0-2000 ppm, 4-20 mA |
| S3922R449A | R449 detector, 0-2000 ppm, 4-20 mA |
| S3655R507A | R507A detector, 0-2000 ppm, 4-20 mA |
| S3672R410A | R410A detector, 0-2000 ppm, 4-20 mA |
| S3951R417A | R417A detector, 0-2000 ppm, 4-20 mA |
| S3955R448 | R448 detector, 0-2000 ppm, 4-20 mA |
| ACCESSORIES | |
| STS/CSW+ | Calibration software for SMART3G, SMART3NC & SMART3R detectors including USB key, USB/RS485 converter and STS/IDI card. Allows alarm threshold changes, range setup, and Zero/Span/4-20 mA calibration via user-friendly interface. |
| STS/IDI | Plug-in interface for RS485 serial communication suitable for SMART3G |
| STGD/AD3 | Adapter for all sensor heads (except S2096__ & S2097__) to upgrade protection from G to GD |
Get in touch with us to see how we can help you with your project